Starters and Switches – Ampkart https://www.ampkart.com Buy Electrical Products Online Easily Tue, 16 Jul 2024 13:01:00 +0000 en-US hourly 1 https://www.ampkart.com/wp-content/uploads/2020/11/ampcart-icon-64x64.png Starters and Switches – Ampkart https://www.ampkart.com 32 32 L&T Tripper 30A 1 Phase Automatic Changeover Switch ACCL https://www.ampkart.com/lt-tripper-30a-1-phase-automatic-changeover-switch-accl/ https://www.ampkart.com/lt-tripper-30a-1-phase-automatic-changeover-switch-accl/#comments Mon, 31 Jul 2023 08:12:56 +0000 https://www.ampkart.com/?post_type=product&p=26201
  • L&T Switchgear 30A Single Phase Automatic Changeover Switch with Current Limiter ACCL
  • CE marked, Conforms to IEC 60947-6, IEC 60947-3
  • No. of Poles 1P+N, for single phase applications
  • Reliable microcontroller based design for sensing and control
  • Protection Degree - IP20, Lower power consumption and RoHS compliant
  • Automatic Changeover (ACCL) 240V AC 50 Hz
  • Modules: 4 ; Can be installed in any standard DB Boxes taking 4 Pole MCB space.
  • ]]>
  • L&T Switchgear 30A Single Phase Automatic Changeover Switch with Current Limiter ACCL
  • CE marked, Conforms to IEC 60947-6, IEC 60947-3
  • No. of Poles 1P+N, for single phase applications
  • Reliable microcontroller based design for sensing and control
  • Protection Degree - IP20, Lower power consumption and RoHS compliant
  • Automatic Changeover (ACCL) 240V AC 50 Hz
  • Modules: 4 ; Can be installed in any standard DB Boxes taking 4 Pole MCB space.
  • ]]>
    https://www.ampkart.com/lt-tripper-30a-1-phase-automatic-changeover-switch-accl/feed/ 2
    Dama 32A TP Main Switch Fuse Unit Rewirable https://www.ampkart.com/dama-32a-tp-main-switch-fuse-unit-rewirable/ https://www.ampkart.com/dama-32a-tp-main-switch-fuse-unit-rewirable/#respond Wed, 12 Jul 2023 13:21:16 +0000 https://www.ampkart.com/?post_type=product&p=26054
  • Voltage: 415V | 32 Ampere Three Pole Main Switch Box
  • Rewireable Main Switch Fuse Unit
  • ]]>
  • Voltage: 415V | 32 Ampere Three Pole Main Switch Box
  • Rewireable Main Switch Fuse Unit
  • ]]>
    https://www.ampkart.com/dama-32a-tp-main-switch-fuse-unit-rewirable/feed/ 0
    Siemens Sinova 30A 1 Phase Automatic Changeover Switch ACCL https://www.ampkart.com/siemens-sinova-30a-1-phase-automatic-changeover-switch-accl/ https://www.ampkart.com/siemens-sinova-30a-1-phase-automatic-changeover-switch-accl/#comments Sat, 27 Aug 2022 07:24:38 +0000 https://www.ampkart.com/?post_type=product&p=21868
  • Siemens Sinova 30A 1 Phase Automatic Changeover Switch cum Current Limiter also known as ACCL
  • 1P + N, 240V Ac, 50 Hz
  • Module Width - 4M; where 1M = 18mm
  • Can be mounted in Standard Enclosures and DB Boxes
  • ]]>
  • Siemens Sinova 30A 1 Phase Automatic Changeover Switch cum Current Limiter also known as ACCL
  • 1P + N, 240V Ac, 50 Hz
  • Module Width - 4M; where 1M = 18mm
  • Can be mounted in Standard Enclosures and DB Boxes
  • ]]>
    https://www.ampkart.com/siemens-sinova-30a-1-phase-automatic-changeover-switch-accl/feed/ 1
    L&T Exora Automatic Changeover Switch ACCL https://www.ampkart.com/lt-exora-automatic-changeover-switch-accl/ https://www.ampkart.com/lt-exora-automatic-changeover-switch-accl/#comments Sat, 25 Jun 2022 07:00:26 +0000 https://www.ampkart.com/?post_type=product&p=21205
  • L&T Switchgear 30-125A Single Phase and Three Phase Automatic Changeover Switch Cum Current Limiter ACCL
  • An automatic changeover device, which on failure of Mains power supply, automatically transfers the Load from Mains power supply to Generator supply.
  • Single Phase ACCL Features:-

    • Wide Range of Current Ratings for 30A 1 Phase ACCL - Generator Side from 1A to 30A
    • Used in Residential Apartments, standalone buildings, and Multi Complexes.
    • Conforms to IEC 60947-6, IEC 60947-3, and RoHS Compliant
  • Three Phase ACCL Features:-

    • Settable overload current limit at DG side
    • Separate power consumption monitoring for Mains & Genset
    • Settable overvoltage & undervoltage protection
    • Settable TPN or SPN mode at the Generator (DG) side
    • Protection against single phasing
    • Used in Residential Apartments, standalone buildings, Multi Complexes, and Commercial Buildings.
  • ]]>
  • L&T Switchgear 30-125A Single Phase and Three Phase Automatic Changeover Switch Cum Current Limiter ACCL
  • An automatic changeover device, which on failure of Mains power supply, automatically transfers the Load from Mains power supply to Generator supply.
  • Single Phase ACCL Features:-

    • Wide Range of Current Ratings for 30A 1 Phase ACCL - Generator Side from 1A to 30A
    • Used in Residential Apartments, standalone buildings, and Multi Complexes.
    • Conforms to IEC 60947-6, IEC 60947-3, and RoHS Compliant
  • Three Phase ACCL Features:-

    • Settable overload current limit at DG side
    • Separate power consumption monitoring for Mains & Genset
    • Settable overvoltage & undervoltage protection
    • Settable TPN or SPN mode at the Generator (DG) side
    • Protection against single phasing
    • Used in Residential Apartments, standalone buildings, Multi Complexes, and Commercial Buildings.
  • ]]>
    https://www.ampkart.com/lt-exora-automatic-changeover-switch-accl/feed/ 3
    L&T Main Switch Disconnecter Fuse Unit TPN https://www.ampkart.com/lt-main-switch-disconnecter-fuse-unit-tpn/ https://www.ampkart.com/lt-main-switch-disconnecter-fuse-unit-tpn/#respond Wed, 01 Jun 2022 11:36:01 +0000 https://www.ampkart.com/?post_type=product&p=20942
  • L&T 32-800A TPN Switch Disconnector Fuse Unit for DIN and Cylindrical HRC Fuses.
  • Range 32A to 800A, 415V, AC 23A
  • Commonly used as Main Switch for Domestic and Commercial Purposes.
  • Terminal Shrouds on both sides and Phase Barriers included
  • Door interlock & padlock facility
  • Conforms to IEC 60947-3, IS/IEC 60947-3
  • TPN SDF has isolable neutral
  • Suitable for Cylindrical/DIN fuse-link which can be purchased separately.
  • ]]>
     

    L&T TPN  Main Switch Disconnector Fuse (SDF) without Enclosure or Open Execution:

      • Range 32A to 800A, 415V, AC 23A
    • Conforms to IEC 60947-3, IS/IEC 60947-3
    • Terminal Shrouds on both sides and Phase Barriers included
    • Telescopic shaft for depth adjustment
    • TPN SDF has isolable neutral
    • 4P SDF has Switched Neutral Pole and is 100% rated
    • Door interlock & padlock facility
    Suitable HRC fuse-link Open Execution Type FN (TPN) S-D-F suitable for DIN fuse-link
    Size Rated Current (A) Type Range (A) Type Cat. No.
    Fr 1 32 Cylindical HF Size 14×51 2 to 32 FN 32 TPN / FP SK95518
    Fr 1 32 Cylindical HF Size 14×51 2 to 32 FN 32 TPN / FP CE* SK95703*
    Fr 1 63 Cylindical HF Size 14×51 2 to 63 FN 63 TPN / FP SK95421
    Fr 1 63 Cylindical HF Size 14×51 2 to 63 FN 63 TPN / FP CE* SK95704*
    Fr 2 100 DIN HN Size 000/00 63 to 100 FN 100 TPN SK95568
    Fr 2 125 DIN HN Size 000/00 63 to 125 FN 125 TPN SK95001
    Fr 2 160 DIN HN Size 000/00 63 to 160 FN 160 TPN SK95713
    Fr 3 200 DIN HN Size 0 80 to 200 FN 200 TPN SK95418
    Fr 3 250 DIN HN Size 1 125 to 250 FN 250 TPN SK95642
    Fr 4 315 DIN HN Size 1 125 to 315 FN 315 TPN SK95461
    Fr 4 400 DIN HN Size 2 200 to 400 FN 400 TPN SK95481
    Fr 5 630 DIN HN Size 3 315 to 630 FN 630 TPN SK95521
    Fr 5 800 DIN HN Size 3 315 to 800 FN 800 TPN SK95679

     

    L&T TPN Main Switch Disconnector Fuse (SDF) with SS Enclosure:

    • Range 32A to 800A, 415V, AC 23A
    • Spacious Sheet Steel Enclosure
    • Separate cable gland box not required
    • Terminal Shrouds on both sides and Phase Barriers included
    • Benefits of 3 in 1:
      • Cable Gland Box Top
      • SDF in Enclosure
      • Cable Gland Box Bottom
    • Conforms to IEC 60947-3, IS/IEC 60947-3
    • Suitable for Cylindrical/DIN fuse-link
    • Door interlock & padlock facility
    • The SDF units in SS enclosure version can be replaced with FN TPN SDF open execution units. Please refer below for replacement of 250A unit
    • For replacement of FN 250 SDF unit in sheet steel enclosure version (Cat. No. SK90489OOOO & SK95681OOOO), order Cat. No. ST97895OOOO

     

    Suitable HRC fuse-link In Sheet Steel Enclosure Type FN (TPN) S-D-F suitable for DIN fuse-link
    Size Rated Current (A) Type Range (A) Type Cat. No.
    Fr 1 32 Cylindical HF Size 14×51 2 to 32 FN 32 TPN / FP CE* SK90483*
    Fr 1 63 Cylindical HF Size 14×51 2 to 63 FN 63 TPN / FP CE* SK90484*
    Fr 2 100 DIN HN Size 000/00 63 to 100 FN 100 TPN SK90485
    Fr 2 125 DIN HN Size 000/00 63 to 125 FN 125 TPN SK90486
    Fr 2 160 DIN HN Size 000/00 63 to 160 FN 160 TPN SK90487
    Fr 3 200 DIN HN Size 0 80 to 200 FN 200 TPN SK90488
    Fr 3 250 DIN HN Size 1 125 to 250 FN 250 TPN SK90489
    Fr 4 315 DIN HN Size 1 125 to 315 FN 315 TPN SK90490
    Fr 4 400 DIN HN Size 2 200 to 400 FN 400 TPN SK90491
    Fr 5 630 DIN HN Size 3 315 to 630 FN 630 TPN SK90492
    Fr 5 800 DIN HN Size 3 315 to 800 FN 800 TPN SK90493
    ]]>
    https://www.ampkart.com/lt-main-switch-disconnecter-fuse-unit-tpn/feed/ 0
    Muller 3 Phase 4 Pole Automatic Changeover Switch ACCL https://www.ampkart.com/muller-3-phase-4-pole-auto-changeover-switch/ https://www.ampkart.com/muller-3-phase-4-pole-auto-changeover-switch/#comments Fri, 03 Sep 2021 13:35:21 +0000 https://www.ampkart.com/?post_type=product&p=16084
  • Muller ACCL or Automatic Changeover Switch is wall mounting type in Powder Coated Mild Steel Enclosure and is suitable for domestic, residential and commercial applications.
  • Customizable Generator Limit to suit your needs
  • Controlled by Muller I.C. Logic circuit with Main ON, DG On, Overload Trip Indicator & provision of Earthling.
  • ]]>
    General Characteristics of Muller ACCLs
    • Muller ACCLs are suitable for Domestic, Residential and Commercial Applications.
    • Wall Mounting Type in Powder Coated Mild Steel Enclosure.
    • Powered by Type Tested Contactor confirming to IEC-60947-4-1.
    • Controlled by Muller I.C. Logic circuit with Main ON, DG On, Overload Trip Indicator & provision of Earthling.
    ]]>
    https://www.ampkart.com/muller-3-phase-4-pole-auto-changeover-switch/feed/ 1
    L&T Manual Changeover Switch On Load https://www.ampkart.com/lt-switchgear-manual-changeover-on-load/ https://www.ampkart.com/lt-switchgear-manual-changeover-on-load/#comments Thu, 27 May 2021 04:12:25 +0000 https://www.ampkart.com/import-placeholder-4/
  • L&T Switchgear 63-2000A 4 Pole On Load Manual Changeover with Front Handle applicable in networks on 415V AC current and is suitable for both horizontal as well as vertical mounting.
  • ]]>
    L&T Switchgear Manual Changeover in Sheet Steel Enclosure Extended Handle Description

    Features and Details:

    • Conforms to IEC 60947-3 | IS/IEC 60947-3
    • Range 63A to 2000A , 415V , AC 23A , 4 Pole
    • The enclosure version does not require a separate cable gland box
    • Terminal Shrouds, Source Separator and Phase Barriers included
    • Staggered Terminals make cable termination easy
    • Suitable for horizontal as well as vertical mounting
    ]]>
    https://www.ampkart.com/lt-switchgear-manual-changeover-on-load/feed/ 1
    HPL Manual Changeover Switch Side Handle in Enclosure https://www.ampkart.com/hpl-manual-changeover-side-handle-in-enclosure/ https://www.ampkart.com/hpl-manual-changeover-side-handle-in-enclosure/#comments Thu, 27 May 2021 04:12:18 +0000 https://www.ampkart.com/import-placeholder-3/
  • HPL 32-400A Manual Changeover Switch with On/Off Load Side Handle in Sheet Steel Enclosure.
  • ]]>
    HPL Manual Changeover Side Handle Description

    Features and Details:

    • In Sheet enclosure | Powder Coated | Weatherproof conforming to IS: 13947 – (Part 3) 1993
    ]]>
    https://www.ampkart.com/hpl-manual-changeover-side-handle-in-enclosure/feed/ 1
    Electron AC Starter Switches 1 Phase Digital OLP3+ https://www.ampkart.com/electron-ac-starter-1-phase-olp3/ https://www.ampkart.com/electron-ac-starter-1-phase-olp3/#respond Thu, 27 May 2021 04:12:02 +0000 https://www.ampkart.com/import-placeholder/
  • Electron 21-30A 1 Phase OLP3+ Air Conditioner starters is an advanced microprocessor-controlled motor starter designed to ensure your air-conditioner's safety and long life using  VOLTCHECK, AMPCHECK, and TIME CHECK.
  • VOLT CHECK - It monitors the line voltage and trips if safety limits of (160-270V) are crossed. The reason for failure and unsafe voltage amount will be displayed if it trips.
  • AMP CHECK - Continuous monitoring of the current drawn by the AC is a key function of the OLP 3+. If the current exceeds a pre-set limit, the output is disconnected. This protection mechanism safeguards the compressor against potential damage. Higher the overload, the quicker the tripping. The overload amount will be displayed if it trips.
  • TIME CHECK - In the event of a trip, it keeps the output open for a duration of 3 minutes starting from the last compressor operation, after which it automatically restarts the AC system. This delay is crucial for ensuring the safety of the compressor. Relevant trip details and Time remaining will be displayed in the event of a trip.
  • It is applicable in networks of 240V AC current.
  • Buy 21A - For 1-2 Ton, 25A - For 2-2.5 Tons, 27A - For 2.5-3 Tons, 30A - For 3 Tons AC Load.
  • ]]>
    Electron Air Conditioner Starter 1 Phase OLP3+ Description
    • Today, air-conditioners are usually the highest energy-consuming appliance in a home, and also one of the most expensive. The all-new OLP 3+ is an advanced microprocessor-controlled motor starter designed to ensure the safety and long life of your air-conditioner using the time-tested combination of VOLTCHECK, AMPCHECK, and TIME CHECK. The vivid 3-digit display shows all operational parameters such as voltage, current, the reason for the trip, and time remaining till reset, for user interest and awareness of their AC’s consumption characteristics. Available in 11A, 16A, 21A, 25A, 27A and 30A configurations.
    Rated Voltage 240V (P-N), 50 Hz, 1 phase
    Rated Current(AC1) Up to 30A
    Under/over-voltage protection 160-270V
    Operating voltage range 90-320 V
    Electrical Endurance(Operations) 100,000
    Enclosure Materials Polycarbonate (Flame-retardant)
    Mounting Type 4-module box
    Mounting Center 120 mm
    Terminal Capacity 10 mm2
    Dimensions in mm(W X H X D) 146 X 88 X 44
    Protection Class IP20
    Ambient Temperature -10°C to 65°C
    Display Parameters Line Voltage, Current, Fault Indication, Time before the restart
    Protection Features VOLTCHECK, AMPCHECK, TIMECHECK

    VOLTCHECK :

    • OLP 3+ monitors the line voltage and trips if safe Rated Current limits (160-270V) are breached. If tripped, the reason (Hi/Lo) and value of unsafe voltage are shown.

    AMPCHECK :

    • Current drawn by the AC is monitored continuously, and the output is disconnected if this exceeds a pre-set limit. This protects against damage due to rotor locking or excessively long start-up time. Tripping follows an inverse time-current characteristic – the higher the overload, the faster the tripping response. After tripping, the overload current is shown on the display.

    TIMECHECK :

    • On tripping, OLP 3+ holds the output open for a duration of 3 minutes from the time of last compressor operation and then restarts the AC automatically. This is an important safety measure for the compressor. When TIME CHECK is active, the display indicates the number of minutes left for Protection Features VOLTCHECK, AMP- AC to restart, along with trip information.
    ]]>
    https://www.ampkart.com/electron-ac-starter-1-phase-olp3/feed/ 0
    HPL TPN Main Fuse Switch Unit with HRC Fuse https://www.ampkart.com/hpl-main-fuse-switch-unit-tpn-with-hrc-fuse/ https://www.ampkart.com/hpl-main-fuse-switch-unit-tpn-with-hrc-fuse/#respond Thu, 20 May 2021 09:30:07 +0000 https://www.ampkart.com/import-placeholder-3/
  • HPL 200A-400A Main Fuse Switch Unit Triple Pole Neutral(TPN) with HRC Fuse which is well protected as they come in sheet enclosure, powder-coated, and weatherproof.
  • Comes with HRC Fuses
  • Voltage - 415V
  • ]]>
    HPL Main Fuse Switch Unit TPN with HRC Fuse

    Features and Details:

    • In Sheet enclosure, Powder Coated, Weatherproof conforming to IS: 13947 – (Part 3) 1993
    • Voltage: 415V
    ]]>
    https://www.ampkart.com/hpl-main-fuse-switch-unit-tpn-with-hrc-fuse/feed/ 0