125A – Ampkart https://www.ampkart.com Buy Electrical Products Online Easily Tue, 16 Jul 2024 13:01:00 +0000 en-US hourly 1 https://www.ampkart.com/wp-content/uploads/2020/11/ampcart-icon-64x64.png 125A – Ampkart https://www.ampkart.com 32 32 HPL HRC Fuse Link BS Bolted https://www.ampkart.com/hpl-hrc-fuse-link-bs-bolted/ https://www.ampkart.com/hpl-hrc-fuse-link-bs-bolted/#respond Fri, 01 Jul 2022 11:06:45 +0000 https://www.ampkart.com/?post_type=product&p=21302
  • 2A-630A BS Bolted Type HRC Fuse Link
  • 415V , 80kA, 50 Hz
  • Used in Bolted Fuse Unit type Main Switches
  • Conforms to IS-13703
  • ]]>
  • 2A-630A BS Bolted Type HRC Fuse Link
  • 415V , 80kA, 50 Hz
  • Used in Bolted Fuse Unit type Main Switches
  • Conforms to IS-13703
  • ]]>
    https://www.ampkart.com/hpl-hrc-fuse-link-bs-bolted/feed/ 0
    L&T Exora Automatic Changeover Switch ACCL https://www.ampkart.com/lt-exora-automatic-changeover-switch-accl/ https://www.ampkart.com/lt-exora-automatic-changeover-switch-accl/#comments Sat, 25 Jun 2022 07:00:26 +0000 https://www.ampkart.com/?post_type=product&p=21205
  • L&T Switchgear 30-125A Single Phase and Three Phase Automatic Changeover Switch Cum Current Limiter ACCL
  • An automatic changeover device, which on failure of Mains power supply, automatically transfers the Load from Mains power supply to Generator supply.
  • Single Phase ACCL Features:-

    • Wide Range of Current Ratings for 30A 1 Phase ACCL - Generator Side from 1A to 30A
    • Used in Residential Apartments, standalone buildings, and Multi Complexes.
    • Conforms to IEC 60947-6, IEC 60947-3, and RoHS Compliant
  • Three Phase ACCL Features:-

    • Settable overload current limit at DG side
    • Separate power consumption monitoring for Mains & Genset
    • Settable overvoltage & undervoltage protection
    • Settable TPN or SPN mode at the Generator (DG) side
    • Protection against single phasing
    • Used in Residential Apartments, standalone buildings, Multi Complexes, and Commercial Buildings.
  • ]]>
  • L&T Switchgear 30-125A Single Phase and Three Phase Automatic Changeover Switch Cum Current Limiter ACCL
  • An automatic changeover device, which on failure of Mains power supply, automatically transfers the Load from Mains power supply to Generator supply.
  • Single Phase ACCL Features:-

    • Wide Range of Current Ratings for 30A 1 Phase ACCL - Generator Side from 1A to 30A
    • Used in Residential Apartments, standalone buildings, and Multi Complexes.
    • Conforms to IEC 60947-6, IEC 60947-3, and RoHS Compliant
  • Three Phase ACCL Features:-

    • Settable overload current limit at DG side
    • Separate power consumption monitoring for Mains & Genset
    • Settable overvoltage & undervoltage protection
    • Settable TPN or SPN mode at the Generator (DG) side
    • Protection against single phasing
    • Used in Residential Apartments, standalone buildings, Multi Complexes, and Commercial Buildings.
  • ]]>
    https://www.ampkart.com/lt-exora-automatic-changeover-switch-accl/feed/ 3
    L&T Main Switch Disconnecter Fuse Unit TPN https://www.ampkart.com/lt-main-switch-disconnecter-fuse-unit-tpn/ https://www.ampkart.com/lt-main-switch-disconnecter-fuse-unit-tpn/#respond Wed, 01 Jun 2022 11:36:01 +0000 https://www.ampkart.com/?post_type=product&p=20942
  • L&T 32-800A TPN Switch Disconnector Fuse Unit for DIN and Cylindrical HRC Fuses.
  • Range 32A to 800A, 415V, AC 23A
  • Commonly used as Main Switch for Domestic and Commercial Purposes.
  • Terminal Shrouds on both sides and Phase Barriers included
  • Door interlock & padlock facility
  • Conforms to IEC 60947-3, IS/IEC 60947-3
  • TPN SDF has isolable neutral
  • Suitable for Cylindrical/DIN fuse-link which can be purchased separately.
  • ]]>
     

    L&T TPN  Main Switch Disconnector Fuse (SDF) without Enclosure or Open Execution:

      • Range 32A to 800A, 415V, AC 23A
    • Conforms to IEC 60947-3, IS/IEC 60947-3
    • Terminal Shrouds on both sides and Phase Barriers included
    • Telescopic shaft for depth adjustment
    • TPN SDF has isolable neutral
    • 4P SDF has Switched Neutral Pole and is 100% rated
    • Door interlock & padlock facility
    Suitable HRC fuse-link Open Execution Type FN (TPN) S-D-F suitable for DIN fuse-link
    Size Rated Current (A) Type Range (A) Type Cat. No.
    Fr 1 32 Cylindical HF Size 14×51 2 to 32 FN 32 TPN / FP SK95518
    Fr 1 32 Cylindical HF Size 14×51 2 to 32 FN 32 TPN / FP CE* SK95703*
    Fr 1 63 Cylindical HF Size 14×51 2 to 63 FN 63 TPN / FP SK95421
    Fr 1 63 Cylindical HF Size 14×51 2 to 63 FN 63 TPN / FP CE* SK95704*
    Fr 2 100 DIN HN Size 000/00 63 to 100 FN 100 TPN SK95568
    Fr 2 125 DIN HN Size 000/00 63 to 125 FN 125 TPN SK95001
    Fr 2 160 DIN HN Size 000/00 63 to 160 FN 160 TPN SK95713
    Fr 3 200 DIN HN Size 0 80 to 200 FN 200 TPN SK95418
    Fr 3 250 DIN HN Size 1 125 to 250 FN 250 TPN SK95642
    Fr 4 315 DIN HN Size 1 125 to 315 FN 315 TPN SK95461
    Fr 4 400 DIN HN Size 2 200 to 400 FN 400 TPN SK95481
    Fr 5 630 DIN HN Size 3 315 to 630 FN 630 TPN SK95521
    Fr 5 800 DIN HN Size 3 315 to 800 FN 800 TPN SK95679

     

    L&T TPN Main Switch Disconnector Fuse (SDF) with SS Enclosure:

    • Range 32A to 800A, 415V, AC 23A
    • Spacious Sheet Steel Enclosure
    • Separate cable gland box not required
    • Terminal Shrouds on both sides and Phase Barriers included
    • Benefits of 3 in 1:
      • Cable Gland Box Top
      • SDF in Enclosure
      • Cable Gland Box Bottom
    • Conforms to IEC 60947-3, IS/IEC 60947-3
    • Suitable for Cylindrical/DIN fuse-link
    • Door interlock & padlock facility
    • The SDF units in SS enclosure version can be replaced with FN TPN SDF open execution units. Please refer below for replacement of 250A unit
    • For replacement of FN 250 SDF unit in sheet steel enclosure version (Cat. No. SK90489OOOO & SK95681OOOO), order Cat. No. ST97895OOOO

     

    Suitable HRC fuse-link In Sheet Steel Enclosure Type FN (TPN) S-D-F suitable for DIN fuse-link
    Size Rated Current (A) Type Range (A) Type Cat. No.
    Fr 1 32 Cylindical HF Size 14×51 2 to 32 FN 32 TPN / FP CE* SK90483*
    Fr 1 63 Cylindical HF Size 14×51 2 to 63 FN 63 TPN / FP CE* SK90484*
    Fr 2 100 DIN HN Size 000/00 63 to 100 FN 100 TPN SK90485
    Fr 2 125 DIN HN Size 000/00 63 to 125 FN 125 TPN SK90486
    Fr 2 160 DIN HN Size 000/00 63 to 160 FN 160 TPN SK90487
    Fr 3 200 DIN HN Size 0 80 to 200 FN 200 TPN SK90488
    Fr 3 250 DIN HN Size 1 125 to 250 FN 250 TPN SK90489
    Fr 4 315 DIN HN Size 1 125 to 315 FN 315 TPN SK90490
    Fr 4 400 DIN HN Size 2 200 to 400 FN 400 TPN SK90491
    Fr 5 630 DIN HN Size 3 315 to 630 FN 630 TPN SK90492
    Fr 5 800 DIN HN Size 3 315 to 800 FN 800 TPN SK90493
    ]]>
    https://www.ampkart.com/lt-main-switch-disconnecter-fuse-unit-tpn/feed/ 0
    Muller 3 Phase 4 Pole Automatic Changeover Switch ACCL https://www.ampkart.com/muller-3-phase-4-pole-auto-changeover-switch/ https://www.ampkart.com/muller-3-phase-4-pole-auto-changeover-switch/#comments Fri, 03 Sep 2021 13:35:21 +0000 https://www.ampkart.com/?post_type=product&p=16084
  • Muller ACCL or Automatic Changeover Switch is wall mounting type in Powder Coated Mild Steel Enclosure and is suitable for domestic, residential and commercial applications.
  • Customizable Generator Limit to suit your needs
  • Controlled by Muller I.C. Logic circuit with Main ON, DG On, Overload Trip Indicator & provision of Earthling.
  • ]]>
    General Characteristics of Muller ACCLs
    • Muller ACCLs are suitable for Domestic, Residential and Commercial Applications.
    • Wall Mounting Type in Powder Coated Mild Steel Enclosure.
    • Powered by Type Tested Contactor confirming to IEC-60947-4-1.
    • Controlled by Muller I.C. Logic circuit with Main ON, DG On, Overload Trip Indicator & provision of Earthling.
    ]]>
    https://www.ampkart.com/muller-3-phase-4-pole-auto-changeover-switch/feed/ 1
    ABB MCCB 25kA https://www.ampkart.com/abb-mccb-25ka/ https://www.ampkart.com/abb-mccb-25ka/#respond Fri, 03 Sep 2021 13:35:20 +0000 https://www.ampkart.com/?post_type=product&p=16083
  • New low voltage MCCB switchgear
  • ]]>
    General Characteristics of ABB MCCBs
    • Conforms to IEC 60974-2
    • Fixed thermal magnetic release throughout the range
    • Compact dimensions and a Common range of accessories
    • Up to 50? no derating and Line-load reversibility
    • Suitable for DC application till 250V DC
    • Operation voltage till 550V AC, insulation voltage of 690V AC, and impulse voltage of 6KV
    ]]>
    https://www.ampkart.com/abb-mccb-25ka/feed/ 0
    L&T Manual Changeover Switch On Load https://www.ampkart.com/lt-switchgear-manual-changeover-on-load/ https://www.ampkart.com/lt-switchgear-manual-changeover-on-load/#comments Thu, 27 May 2021 04:12:25 +0000 https://www.ampkart.com/import-placeholder-4/
  • L&T Switchgear 63-2000A 4 Pole On Load Manual Changeover with Front Handle applicable in networks on 415V AC current and is suitable for both horizontal as well as vertical mounting.
  • ]]>
    L&T Switchgear Manual Changeover in Sheet Steel Enclosure Extended Handle Description

    Features and Details:

    • Conforms to IEC 60947-3 | IS/IEC 60947-3
    • Range 63A to 2000A , 415V , AC 23A , 4 Pole
    • The enclosure version does not require a separate cable gland box
    • Terminal Shrouds, Source Separator and Phase Barriers included
    • Staggered Terminals make cable termination easy
    • Suitable for horizontal as well as vertical mounting
    ]]>
    https://www.ampkart.com/lt-switchgear-manual-changeover-on-load/feed/ 1
    L&T Exora MCCB DY 10kA https://www.ampkart.com/lt-switchgear-tripper-mccb-10ka/ https://www.ampkart.com/lt-switchgear-tripper-mccb-10ka/#respond Wed, 26 May 2021 10:29:31 +0000 https://www.ampkart.com/import-placeholder/
  • L&T Switchgear Tripper 16-200A MCCB with breaking capacity of 10kA operating in 415V AC network current with Thermal Magnetic Release and On-Off Indication.
  • ]]>
    L&T Switchgear Tripper MCCB 10kA Description

    Features and Details:

    • Phase Barriers are provided with all DY125U & DY250U1 MCCBs
    • Thermal Magnetic Release
    • 415 V AC
    • ON -TRIP-OFF indication
    • High Electrical and Mechanical Life
    • Suitable for Isolation
    • No Load-Line Bias
    ]]>
    https://www.ampkart.com/lt-switchgear-tripper-mccb-10ka/feed/ 0
    Schneider Acti9 MCB 10kA ‘C’ https://www.ampkart.com/schneider-electric-acti9-mcb-10ka-c/ https://www.ampkart.com/schneider-electric-acti9-mcb-10ka-c/#comments Thu, 20 May 2021 09:29:50 +0000 https://www.ampkart.com/import-placeholder/
  • Schneider Electric Acti9 6-125A MCBs with a breaking capacity of 10kA and operating on a C-curve.
  • ]]>
    Schneider Electric Acti9 MCB 10kA ‘C’ Description

    Features and Details:

    Schneider Electric Acti9 MCB 10ka ‘C’

    • Breaking capacity as per IEC 60898 | Icn = 10kA
    • Positive Contact Indication for assurance of disconnection
    • Degree of pollution: 3 (suitable for the industrial environment)
    • Operating Temperature: -30 to 70C
    • Terminal connections: Flexible cables up to 35 sq.mm; Rigid cables up to 50 sq.mm

    Schneider Electric Acti9 6-63A MCB 10kA ‘C’ xC60

    • Breaking Capacity as per IEC 60898 and IS/IEC 60898-1, Icn = 10kA
    • Can be used for DC application upto 60V per pole
    • Higher system performance with optimized cost: Cascading
    • Increased System Continuity: Discrimination
    • Higher Installation Life: Energy Limitation Class 3, Fast Closure Mechanism
    • Ease, Speed and Flexibility of installation – Biconnect, Line-Load Reversible
    • Field-fittable auxiliaries for advance protection and monitoring
    • Positive Contact Indication for assurance of disconnection
    ]]>
    https://www.ampkart.com/schneider-electric-acti9-mcb-10ka-c/feed/ 2
    Schneider Acti9 Isolator https://www.ampkart.com/schneider-electric-acti9-isolator/ https://www.ampkart.com/schneider-electric-acti9-isolator/#comments Thu, 20 May 2021 09:28:05 +0000 https://www.ampkart.com/import-placeholder-2/
  • Schneider Electric Acti9 40-125A Isolators are suitable for isolating current networks.
  • ]]>
    Schneider Electric Acti9 Isolator Description

    Features and Details:

    • Complies to IEC/EN 60947-3
    • Switching duty: AC-22
    • Impulse voltage: 6kV
    • DC application: 48V (110V with 2 poles in series)
    • Short circuit withstand 20 In for 1 second
    • Up to 80A Bi connect terminals & 100A to 125A with mono connect terminals
    ]]>
    https://www.ampkart.com/schneider-electric-acti9-isolator/feed/ 2
    Legrand DPX3 MCCB 25kA https://www.ampkart.com/legrand-dpx3-mccb-25ka/ https://www.ampkart.com/legrand-dpx3-mccb-25ka/#respond Thu, 20 May 2021 03:47:58 +0000 https://www.ampkart.com/import-placeholder-2/
  • Legrand DPX3 63-250A MCCB with Thermal Magnetic Protection Unit
  • ]]>
    Legrand MCCB DPX3 25kA

    Features and Details:

    • DPX3 MCCB with Thermal Magnetic Protection Unit: O/L & S/C protection
    • Range: 16A ? 1250A, Ics=100%Icu, Four Optimum Frames
    • Thermal Adjustable ? 0.8 to 1In, Magnetic Adjustable ? 5 to 10In ( Fixed at 10In for DPX3 160)
    • Option for add on module for Earth Leakage Protection
    • Adjustable sensitivity: 0.03 – 0.3 – 1 – 3 A
    • Adjustable tripping: 0 – 0.3 – 1 – 3s
    • Suitable for Isolation
    ]]>
    https://www.ampkart.com/legrand-dpx3-mccb-25ka/feed/ 0