L&T TPN Main Switch Disconnector Fuse (SDF) without Enclosure or Open Execution:
-
- Range 32A to 800A, 415V, AC 23A
- Conforms to IEC 60947-3, IS/IEC 60947-3
- Terminal Shrouds on both sides and Phase Barriers included
- Telescopic shaft for depth adjustment
- TPN SDF has isolable neutral
- 4P SDF has Switched Neutral Pole and is 100% rated
- Door interlock & padlock facility
Suitable HRC fuse-link | Open Execution Type FN (TPN) S-D-F suitable for DIN fuse-link | ||||
Size | Rated Current (A) | Type | Range (A) | Type | Cat. No. |
Fr 1 | 32 | Cylindical HF Size 14×51 | 2 to 32 | FN 32 TPN / FP | SK95518 |
Fr 1 | 32 | Cylindical HF Size 14×51 | 2 to 32 | FN 32 TPN / FP CE* | SK95703* |
Fr 1 | 63 | Cylindical HF Size 14×51 | 2 to 63 | FN 63 TPN / FP | SK95421 |
Fr 1 | 63 | Cylindical HF Size 14×51 | 2 to 63 | FN 63 TPN / FP CE* | SK95704* |
Fr 2 | 100 | DIN HN Size 000/00 | 63 to 100 | FN 100 TPN | SK95568 |
Fr 2 | 125 | DIN HN Size 000/00 | 63 to 125 | FN 125 TPN | SK95001 |
Fr 2 | 160 | DIN HN Size 000/00 | 63 to 160 | FN 160 TPN | SK95713 |
Fr 3 | 200 | DIN HN Size 0 | 80 to 200 | FN 200 TPN | SK95418 |
Fr 3 | 250 | DIN HN Size 1 | 125 to 250 | FN 250 TPN | SK95642 |
Fr 4 | 315 | DIN HN Size 1 | 125 to 315 | FN 315 TPN | SK95461 |
Fr 4 | 400 | DIN HN Size 2 | 200 to 400 | FN 400 TPN | SK95481 |
Fr 5 | 630 | DIN HN Size 3 | 315 to 630 | FN 630 TPN | SK95521 |
Fr 5 | 800 | DIN HN Size 3 | 315 to 800 | FN 800 TPN | SK95679 |
L&T TPN Main Switch Disconnector Fuse (SDF) with SS Enclosure:
- Range 32A to 800A, 415V, AC 23A
- Spacious Sheet Steel Enclosure
- Separate cable gland box not required
- Terminal Shrouds on both sides and Phase Barriers included
- Benefits of 3 in 1:
- Cable Gland Box Top
- SDF in Enclosure
- Cable Gland Box Bottom
- Conforms to IEC 60947-3, IS/IEC 60947-3
- Suitable for Cylindrical/DIN fuse-link
- Door interlock & padlock facility
- The SDF units in SS enclosure version can be replaced with FN TPN SDF open execution units. Please refer below for replacement of 250A unit
- For replacement of FN 250 SDF unit in sheet steel enclosure version (Cat. No. SK90489OOOO & SK95681OOOO), order Cat. No. ST97895OOOO
Suitable HRC fuse-link | In Sheet Steel Enclosure Type FN (TPN) S-D-F suitable for DIN fuse-link | ||||
Size | Rated Current (A) | Type | Range (A) | Type | Cat. No. |
Fr 1 | 32 | Cylindical HF Size 14×51 | 2 to 32 | FN 32 TPN / FP CE* | SK90483* |
Fr 1 | 63 | Cylindical HF Size 14×51 | 2 to 63 | FN 63 TPN / FP CE* | SK90484* |
Fr 2 | 100 | DIN HN Size 000/00 | 63 to 100 | FN 100 TPN | SK90485 |
Fr 2 | 125 | DIN HN Size 000/00 | 63 to 125 | FN 125 TPN | SK90486 |
Fr 2 | 160 | DIN HN Size 000/00 | 63 to 160 | FN 160 TPN | SK90487 |
Fr 3 | 200 | DIN HN Size 0 | 80 to 200 | FN 200 TPN | SK90488 |
Fr 3 | 250 | DIN HN Size 1 | 125 to 250 | FN 250 TPN | SK90489 |
Fr 4 | 315 | DIN HN Size 1 | 125 to 315 | FN 315 TPN | SK90490 |
Fr 4 | 400 | DIN HN Size 2 | 200 to 400 | FN 400 TPN | SK90491 |
Fr 5 | 630 | DIN HN Size 3 | 315 to 630 | FN 630 TPN | SK90492 |
Fr 5 | 800 | DIN HN Size 3 | 315 to 800 | FN 800 TPN | SK90493 |
What is the Main Switch?
The main switch is the part of a control panel that significantly impacts the progress of a project, and applies or disconnects power to the control panel.
The main switch is a central switch that controls small switches and machines in a building. The main switch can be cut by a human or computerized system to control the energy flow through the building.
The main switch, also known as the switchboard, divides the electrical supply to an auxiliary circuit and provides a protection fuse for each circuit. If any circuit is overloaded, the main switch fuse is tripped. This effectively prevents the power supply from circulating in the circuit and prevents the ignition from overloading. In the absence of the master switch, overload would heat the wire, melt the insulation, and eventually ignite the flame.
The "master or master switch" is the name of the master switch that connects or disconnects all circuits to your home. In a circuit breaker box the first and biggest switch is usually the main (about 60 to 100 amps) and under it or to the side is a row of smaller breakers, maybe 10 or 15 or 20 amps each, that go to each area of the house, like kitchen, or bathroom, or living room lights, or living room sockets.
When we look at the sign from the outside, one of the first things we see is something called a ‘master switch' sometimes called an insulator.
The main switch applies or disconnects the 3 phase power that we have in the control panel.
We usually designate only 3 phases with the next labeling system; L1, L2, and L3 are the 3 phases of procurement. “N” is the neutral wire. The goal of the neutral leads is to provide a return path to the electric ground to complete the circuit.